Skip to main content

 Vertical Laminar Flow Cabinets

67OFL, 87OFL, FL-1, FL-2

To ensure the reliability of the tests, it is essential that the work carried out inside the cabinet does not become contaminated. To create an environment that is safe and particle-free, the vertical laminar flow cabinets we manufacture produce a stream of Class ISO 5 sterile air. This air passes through a H14 HEPA filter (manufactured pursuant to Standard EN-1822) at a constant speed, travelling downward through the cabinet in a vertical laminar flow and producing sterile air, protecting the product from external contamination and possible cross-contamination between samples.

The cabinets that are equipped with our filtration system, which has a minimum efficiency rate of 99.995% for 0.3 µm particles in the upper part of the filter and an extraction rate of 100% as regards the air flow to the outside.

Sample Protection. Total Sterility

Our vertical laminar flow cabinets guarantee a laminar stream of air with class ISO 5 air purity pursuant to Standard EN14644-1 thanks to our intelligent H14 HEPA filters, providing a minimum efficiency rate of 99.995% for 0.3 µm particles.

Flexible

These can be used in areas where it is difficult to extract contaminated air, such as the lower floors of buildings, and they can be placed in different locations, which it means that they can be easily relocated if needed.

Economic Savings and Easy to Set-Up

No expensive works are necessary to install the cabinet which means there are no additional costs and no need to interrupt a laboratory working at full capacity.

Energy Savings

Unlike other brands, our cabinets do not consume the air conditioning of the laboratory, which substantially reduces energy costs: the filtered air is not expelled to the outside, but recirculated back into the laboratory free of contaminating particles.

Features

Yes, they all fit and are standard.

Manufacture: the external surfaces are made of cold-rolled steel, coated with white epoxy, enamelled in ovens at 200ºC and resistant to the chemical compounds used for sterilization.

Work Surface: the surface of the work chamber is made of white secured glass, highly resistant to impacts and chemical attacks.

Absolute H14 HEPA Filter with a flow equalizer and an efficiency rate of over 99.995% for particles measuring 0.3 microns. Standards MIL-F51068C and BS 3298.

Fan motors: double aspiration centrifugal fans, capable of providing a laminar flow in the work space, above all as regards dealing with filter saturation to a maximum value of 400 Pascal.

Control Panel: Soft-touch keyboard with a switch for the LED lamps, UV ultraviolet lights, a maintenance system to control the airspeed through the HEPA filter that is electronically self-regulated and a control key to reduce speed in ECO mode.

Lighting: LED lamps located in the centre with a prismatic diffusing screen to improve the distribution of light on the work surface.

Control pannel with big size LCD Display Cruma Fume Hoods Detail
Open door photocell system Cruma Fume Hoods Detail
LED lighting 900 LUX Cruma Fume Hoods Detail
Serial UV Lamp 15W
Optional Vacuum tap
Optional Gas tap
Serial electrical socket
Closing door
Optional tubular stand

Uses

But we’re sure you’ll find more.

  • Laboratory food industries in general
  • Transfer of drugs in the pharmacy department
  • Hematology and clinical analysis
  • Filled with antibiotics and injectable drugs (except cytostatic) microscopic analysis
  • Tissue culture bags reconstitution of parenteral methods of assisted fertilization techniques
  • Micropropagation, Plant cell cultures, Water quality control, manufacturing of electronic devices…

127x34mm LCD Display

Type of filter installed
Working hours
Wxpiration date and next revision date
Countdown timer
Clock and Calendar

New features and components

Initial cycle flow adequacy and final purge cycle
Fault LED
Control of air flow through Microprocessor
HEPA filters with electronic chip
LED illumination

New alarms and scheduled warnings

Next validation warning
Few hours of filter life warning
Countdown timer warning
Expired filter alarm by hours & by date
Equipment without filter alarm

I Want more Information and Prices

    Accept the privacy policy



    *Required fields

    Clean Area

    Protect your samples without cross contamination.

    In the vertical laminar flow cabinets the stream of air passes through the H14 HEPA filter (manufactured pursuant to EN-1822) at a constant speed, travelling vertically through the cabinet in a laminar flow and producing a Class ISO 5 sterile environment (former American Federal Standard 209E) and protecting the product from external contamination and possible cross-contamination between samples.

    Single-stage filtration system with a minimum efficiency rate of 99.995% for particles of 0.3 µm in the upper part with an extraction rate of 100% as regards the air flow to the outside. Total protection for the sample.

    Models and Technical Specifications

    All sizes for all needs.

    Model 670FL 870FL FL-1 FL-2
    Internal Sizes (Width/Depth/High) 575x560x630 775x560x740 710x556x610 1110x556x610
    Medidas externas (Width/Depth/High) 600x600x930 800x600x1125 800x600x1137 1200x600x1137
    Filter columns
    Filter number 1 1 1 1
    Fans 1 1 1 1
    Average volume of treated air/hour
    Average face velocity 0.35 m/s 0.35 m/s 0.40 m/s 0.40 m/s
    Internal volume of the cabinet 0.181m3 0.287m3 0.236m3 0.376m3
    Renewals inside the cabinet/min.
    Total electrical power consumption 55 W 55 W 226 W 226 W
    Voltage-Frequency 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz 110-220 V / 50-60 Hz
    LED light intensity 1300 lm 15 W 1300 lm 15 W 900 Lux 16 W 900 Lux 16 W
    UV Lamp 1x15W 1x15W 1x15W 1x15W
    Sound level 57 ±3 dB 50 ±3 dB 50 dB 50 dB
    Weight 65 Kg 92 Kg 112 Kg 142 Kg
    Packaging volume 0.28 m3 0.42 m3 0.74 m3 0.95 m3
    Download Technical Specs PDF TECHNICAL DATA SHEET 670FL TECHNICAL DATA SHEET 870FL TECHNICAL DATA SHEET FL-1 TECHNICAL DATA SHEET FL-2
    OFFER REQUEST I WANT MORE INFO & PRICES I WANT MORE INFO & PRICES I WANT MORE INFO & PRICES I WANT MORE INFO & PRICES

    I Want more Information and Prices

      Accept the privacy policy



      *Required fields

      Serial Equipment

      Full Equip Cabinets

      Equipment Description
      Electronic circuit with large format LCD display Security levels: level 1 for users and level 2 for maintenance users
      Filters controlled by microprocessor The filters are provided with a  microchip with mini USB connection identifying the type of filter installed, the expiry date and the serial number
      Illumination 96 LED high light intensity and low consumption 16 Watts / 900 Lux
      Digital timer with audible warning Hourmeter for the control and warning of the work in the cabinet
      Clock and Calendar Display of date and time
      Work surface 1 Liquid retention tray (2-10 liters) with working surface in white tempered glass
      HEPA H-14 filter Manufactured according to EN 1822 with a minimum efficiency of 99.998% for particles of 0.3 microns
      G4 Prefilter Pre-filtering class G4 biofibre synthetic blanket
      Warranty 7 years

      Optional

      Details that matter.

      Equipment Description
      Movilair Stand with wheels and internal tray in Epoxy coated steel
      Tubular steel stand Support stand in Epoxy coated steel
      Working surface 2 Spill retention tray (2-10 liters) with working surface in phenolic resin
      Working surface 3 Spill retention tray (2-10 liters) with working surface in inox steel
      Transparent rear back pannel Transparent polymethylmethacrylate rear pannel 8 mm thick (light transmission of 93%). Ideal for teaching sessions.
      Voltage / Frequency 125 V / 50 Hz
      Filter test kit Dräger pump with reactive colorimetric tubes (pack 10u)

      Cruma Filters

      HEPA filter H-14 for a pure air. Pristine air.

      Absolute H14 HEPA Filter with a flow equalizer and an efficiency rate of over 99.995% for particles measuring 0.3 microns. Standards MIL-F51068C and BS 3298. With an electronic chip to provide both the operators and the samples with the greatest possible degree of safety.

      * To view the technical sheets of our filters, please contact Cruma sales department at export@cruma.es
      – It is the user’s responsibility to correctly manage the waste generated from filters based on the use given to them and according to the applicable requirements.
      – The supply of spare parts is guaranteed during a period of 10 years

      I want more information and prices

        Accept the privacy policy



        *Required fields

        Any doubt about what to choose?  Take our fantastic test!